{"product_id":"universal-testing-machine-50-kn-for-sheet-metal-testing-copy","title":"Universal Testing Machine 50 kN for Sheet Metal Testing","description":"\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 14.0pt; line-height: 115%;\"\u003eUniversal Testing Machine for Sheet Metal Tensile Testing up to 50 kN\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe ProLine Z050 TN is a compact universal testing machine for standardized materials testing. This sheet metal testing configuration combines a maximum test load of 50 kN with wedge grips and a choice of clip-on or makroXtens extensometer.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIts rigid two-column frame, accurate force measurement, and intuitive testXpert III software help you perform routine tests consistently and efficiently.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cb\u003eKey features:\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eProLine is the ideal testing machine for function tests on components and standard tests on materials.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eProLine employs a high-quality two-column load frame with steel columns for precise crosshead guidance.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eHigh-quality, maintenance-free AC drive technology and online correction of machine compliance enable highly accurate travel-measurement and positioning.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eSpecially matched extensometers, test fixtures and specimen grips.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eNominal force 50 kN\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eTest area (W x H) 440 x 1370 mm\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eHigh test-speed (0.0005 ... 600 mm\/min) right up to nominal force\u003cb\u003e\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eInnovative testControl II electronics\u003cb\u003e\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cb\u003eIncluded Accessories:\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan lang=\"DE\" style=\"mso-font-kerning: 0pt; mso-ligatures: none; mso-ansi-language: DE;\"\u003eXforce P Load Cell\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eForce range: 200 N...50 kN\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eHigh-precision load cell with wide measurement range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eMinimized sensitivity to parasitic forces\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eExtremely robust, high operating force up to 150% of capacity\u003c\/span\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBody Over Wedge Grips\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003c!--[endif]--\u003e\u003cspan style=\"mso-bidi-font-family: Arial; mso-font-kerning: 0pt; mso-ligatures: none; mso-bidi-font-weight: bold;\"\u003eBody over wedge grip, Fmax 50 kN\u003c\/span\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none; mso-bidi-font-weight: bold;\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eMax. Opening width 25 mm (dependent on the jaws)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan lang=\"DE\" style=\"mso-font-kerning: 0pt; mso-ligatures: none; mso-ansi-language: DE;\"\u003eTemperature range -40...+250 ⁰C\u003c\/span\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb style=\"mso-bidi-font-weight: normal;\"\u003e\u003cspan lang=\"DE\" style=\"mso-bidi-font-family: Arial; mso-font-kerning: 0pt; mso-ligatures: none; mso-ansi-language: DE;\"\u003eChoose your extensometer\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cb style=\"mso-bidi-font-weight: normal;\"\u003e\u003cspan lang=\"DE\" style=\"mso-bidi-font-family: Arial; mso-font-kerning: 0pt; mso-ligatures: none; mso-ansi-language: DE;\"\u003eVersion: \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan lang=\"DE\" style=\"mso-bidi-font-family: Arial; mso-font-kerning: 0pt; mso-ligatures: none; mso-ansi-language: DE;\"\u003e\u003cspan lang=\"DE\" style=\"mso-font-kerning: 0pt; mso-ligatures: none; mso-ansi-language: DE;\"\u003eClip-on extensometer\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan lang=\"DE\" style=\"mso-bidi-font-family: Arial; mso-font-kerning: 0pt; mso-ligatures: none; mso-ansi-language: DE;\"\u003e\u003cspan lang=\"DE\" style=\"mso-font-kerning: 0pt; mso-ligatures: none; mso-ansi-language: DE;\"\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eManually attaches directly to the specimen for strain measurement.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eFor tests on metals, rigid plastics and composites \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-family: 'HelveticaNeueLT Std Lt Cn',sans-serif; mso-fareast-font-family: 'HelveticaNeueLT Std Lt Cn'; mso-bidi-font-family: 'HelveticaNeueLT Std Lt Cn'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e­\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eMeets the increased requirements for the determination of the tensile modulus according to ISO527-1 Annex C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eFast, easy extensometer attachment and\u003cspan style=\"mso-spacerun: yes;\"\u003e   \u003c\/span\u003eremoval with convenient one-handed operation, even while wearing glove\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eInitial gauge-length automatically locked on attachment and removal, eliminating operator influence\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003c!--[endif]--\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eCompact design allows use even in narrow temperature chambers\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eSingle-sided strain gauge system\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eAccuracy Class 0.5 to EN ISO 9513 up to 15 mm measurement travel\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eAccuracy Class 1 to EN ISO 9513 up to 25 mm measurement travel \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eInitial gauge length 50 mm or 2 inches\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eMeasurement travel for tensile tests 25 mm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-family: 'HelveticaNeueLT Std Lt Cn',sans-serif; mso-fareast-font-family: 'HelveticaNeueLT Std Lt Cn'; mso-bidi-font-family: 'HelveticaNeueLT Std Lt Cn'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e­\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eMeasurement travel for compression tests 5 mm \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-family: 'HelveticaNeueLT Std Lt Cn',sans-serif; mso-fareast-font-family: 'HelveticaNeueLT Std Lt Cn'; mso-bidi-font-family: 'HelveticaNeueLT Std Lt Cn'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e­\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"font-family: 'HelveticaNeueLT Std Lt Cn',sans-serif; mso-fareast-font-family: 'HelveticaNeueLT Std Lt Cn'; mso-bidi-font-family: 'HelveticaNeueLT Std Lt Cn'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e­\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eFlat specimens up to 20 mm thickness, 32 mm width (dependent on jaw insert)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eOverall height: 90 mm\u003c\/span\u003e\u003cspan style=\"font-size: 11.0pt; mso-bidi-font-family: Arial; mso-bidi-font-weight: bold;\"\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eWeight 118 g\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cb style=\"mso-bidi-font-weight: normal;\"\u003e\u003cspan lang=\"DE\" style=\"mso-bidi-font-family: Arial; mso-font-kerning: 0pt; mso-ligatures: none; mso-ansi-language: DE;\"\u003eVersion: \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan lang=\"DE\" style=\"mso-bidi-font-family: Arial; mso-font-kerning: 0pt; mso-ligatures: none; mso-ansi-language: DE;\"\u003e\u003cspan lang=\"DE\" style=\"mso-font-kerning: 0pt; mso-ligatures: none; mso-ansi-language: DE;\"\u003eProLine makroXtens extensometer\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003e\u003cspan lang=\"DE\" style=\"mso-bidi-font-family: Arial; mso-font-kerning: 0pt; mso-ligatures: none; mso-ansi-language: DE;\"\u003e\u003cspan lang=\"DE\" style=\"mso-font-kerning: 0pt; mso-ligatures: none; mso-ansi-language: DE;\"\u003eThe ProLine makroXtens HP is a high-resolution extensometer for tensile tests on metals, plastics, hard foam materials, and materials with low to average specimen strain.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eDeformation of the specimen is recorded in the elastic and plastic deformation range throughout the entire test until specimen break. Low drag force and the ability to adjust the contact force of the sensor arms as needed means you can test sensitive specimens reliably and with traceability.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eVery high resolution and measurement accuracy over the entire measurement range. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eTiltable knife edges prevent damage to the sensor arms and knife edges at specimen break.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eThe knife edge geometry can be adjusted easily and without tools by rotating the knife edges, allowing you to test flat as well as round specimens.\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eQuick release fastener for sensor arms, enabling them to be replaced without the use of tools.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eThe sensor arm clamping force can be adjusted step lessly.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eCentricity is automatically ensured by positioning in the test area. Accuracy class 0.5 to EN ISO 9513. Meets the requirements to ISO 527-1 for determination of the tensile modulus\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003etestXpert III testing software\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"MsoNormal\"\u003eIntegrated user management for role-specific access\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eIntelligent wizard for configuration of all test-relevant settings\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eRepeatable test conditions and check function for connected sensors\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eCompatible with Windows operating system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe following testXpert III functions are included with the testing machine:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan style=\"mso-bidi-font-size: 10.0pt; line-height: 115%; mso-bidi-font-family: Arial; mso-ansi-language: EN-US;\"\u003eTest programs for determining the \u003c\/span\u003e\u003cspan style=\"mso-bidi-font-size: 10.0pt; line-height: 115%; mso-bidi-font-family: Arial; mso-ansi-language: EN-US;\"\u003emaximum force and extension\u003cspan style=\"mso-spacerun: yes;\"\u003e  \u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan style=\"mso-bidi-font-size: 10.0pt; line-height: 115%; mso-bidi-font-family: Arial; mso-ansi-language: EN-US;\"\u003ePerformance and recording of a manual test\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan style=\"mso-bidi-font-size: 10.0pt; line-height: 115%; mso-bidi-font-family: Arial; mso-ansi-language: EN-US;\"\u003eSubsequent evaluation of specimens \u003c\/span\u003e\u003cspan style=\"mso-bidi-font-size: 10.0pt; line-height: 115%; mso-bidi-font-family: Arial; mso-ansi-language: EN-US;\"\u003eand series for calculation under changed \u003c\/span\u003e\u003cspan style=\"mso-bidi-font-size: 10.0pt; line-height: 115%; mso-bidi-font-family: Arial; mso-ansi-language: EN-US;\"\u003especifications or the creation \u003c\/span\u003e\u003cspan style=\"mso-bidi-font-size: 10.0pt; line-height: 115%; mso-bidi-font-family: Arial; mso-ansi-language: EN-US;\"\u003eof new results\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan style=\"mso-bidi-font-size: 10.0pt; line-height: 115%; mso-bidi-font-family: Arial; mso-ansi-language: EN-US;\"\u003eTolerance monitoring of all results\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan style=\"mso-bidi-font-size: 10.0pt; line-height: 115%; mso-bidi-font-family: Arial; mso-ansi-language: EN-US;\"\u003eComplete statistical evaluation of the \u003c\/span\u003e\u003cspan style=\"mso-bidi-font-size: 10.0pt; line-height: 115%; mso-bidi-font-family: Arial; mso-ansi-language: EN-US;\"\u003etest results and tolerance monitoring\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan style=\"mso-bidi-font-size: 10.0pt; line-height: 115%; mso-bidi-font-family: Arial; mso-ansi-language: EN-US;\"\u003eForce and strain control \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan style=\"mso-bidi-font-size: 10.0pt; line-height: 115%; mso-bidi-font-family: Arial; mso-ansi-language: EN-US;\"\u003eOperator and specimen protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan style=\"mso-bidi-font-size: 10.0pt; line-height: 115%; mso-bidi-font-family: Arial; mso-ansi-language: EN-US;\"\u003eFull CSV and ASCII export of \u003c\/span\u003e\u003cspan style=\"mso-bidi-font-size: 10.0pt; line-height: 115%; mso-bidi-font-family: Arial; mso-ansi-language: EN-US;\"\u003eparameters, results and raw data\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan style=\"mso-bidi-font-size: 10.0pt; line-height: 115%; mso-bidi-font-family: Arial; mso-ansi-language: EN-US;\"\u003ePre-defined test report in PDF format\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan style=\"mso-bidi-font-size: 10.0pt; line-height: 115%; mso-bidi-font-family: Arial; mso-ansi-language: EN-US;\"\u003eUser management for protection against \u003c\/span\u003e\u003cspan style=\"mso-bidi-font-size: 10.0pt; line-height: 115%; mso-bidi-font-family: Arial; mso-ansi-language: EN-US;\"\u003eunauthorized use of the testing machine \u003c\/span\u003e\u003cspan style=\"mso-bidi-font-size: 10.0pt; line-height: 115%; mso-bidi-font-family: Arial; mso-ansi-language: EN-US;\"\u003eand test data\u003cspan style=\"mso-spacerun: yes;\"\u003e  \u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan style=\"mso-bidi-font-size: 10.0pt; line-height: 115%; mso-bidi-font-family: Arial; mso-ansi-language: EN-US;\"\u003eReal-time correction of the \u003c\/span\u003e\u003cspan style=\"mso-bidi-font-size: 10.0pt; line-height: 115%; mso-bidi-font-family: Arial; mso-ansi-language: EN-US;\"\u003emachine deformation (correction curve) \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan style=\"mso-bidi-font-size: 10.0pt; line-height: 115%; mso-bidi-font-family: Arial; mso-ansi-language: EN-US;\"\u003eDirect connection of specimen measuring devices \u003c\/span\u003e\u003cspan style=\"mso-bidi-font-size: 10.0pt; line-height: 115%; mso-bidi-font-family: Arial; mso-ansi-language: EN-US;\"\u003eto testXpert III\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cb\u003eOptional Accessories:\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSafety Door for Use with makroXtens Extensometer\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe swiveling front safety door helps protect the operator from fragments and other hazards caused by specimens during testing. Electrical interlocking and mechanical guard locking prevent the door from opening during a test or while hazardous machine movement or test forces remain.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe door features a replaceable, 6 mm polycarbonate panel and a left-side pivot for access to the test area.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eRequired for applications that present a risk of injury to the operator.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSafety Door for Use with Clip-On Extensometer Including Capture Device\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"EN-US\"\u003eThe swiveling front safety door helps protect the operator from specimen fragments and other specimen-related hazards. Electrical interlocking and mechanical guard locking prevent the door from opening during testing or while hazardous machine movement or test forces remain.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"EN-US\"\u003eThe safety door is required for applications that present a risk of injury to the operator.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"EN-US\"\u003eThe safety shield\u003cstrong\u003e includes a device for removal before break without opening the safety device\u003c\/strong\u003e. The clip-on is gently removed from the specimen by a cord and captured by a second cord.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003e\u003cspan lang=\"EN-US\"\u003eBase\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"EN-US\"\u003eBase for ProLine Z030 to Z100\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan lang=\"EN-US\"\u003eFor installation of the testing machine at an ergonomic operating height\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan lang=\"EN-US\"\u003eHeight: 486 mm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan lang=\"EN-US\"\u003eWith drawer for loads up to 50 kg\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan lang=\"EN-US\"\u003eEstimated weight of the testing machine Proline Z050 TN in case of customer-supplied equipment approx. \u003c\/span\u003e450 kg.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"ZwickRoell","offers":[{"title":"Clip-on \/ Factory Calibrated (no extra cost)","offer_id":51924783956135,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"Clip-on \/ ISO","offer_id":51924783988903,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"Clip-on \/ DAkkS","offer_id":51924784021671,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"makroXtens \/ Factory Calibrated (no extra cost)","offer_id":51924784054439,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"makroXtens \/ ISO","offer_id":51924784087207,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true},{"title":"makroXtens \/ DAkkS","offer_id":51924784119975,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/2688\/5031\/files\/UTM50kNSheetMetal.png?v=1794301522","url":"https:\/\/shop.zwickroell.com\/en-us\/products\/universal-testing-machine-50-kn-for-sheet-metal-testing-copy","provider":"ZwickRoell","version":"1.0","type":"link"}