{"title":"ASTM D882 Film Tensile Test","description":"\u003cp\u003e\u003cstrong\u003eASTM D882\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a standard test method for determining the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etensile properties of thin plastic films\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith a thickness of less than 1.0 mm (0.04 in) and is of great importance in the film packaging industry, both for quality control and research and development.\u003c\/p\u003e\n\u003cp\u003eBelow you will find an overview of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eASTM D882\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith regard to the use and significance of the standard, test specimens, test procedure and required test equipment, results and key figures. For full information on ASTM D882, it is essential to\u003cspan\u003e \u003c\/span\u003epurchase the standard.\u003c\/p\u003e\n\u003cp\u003eThe ISO equivalent,\u003cspan\u003e \u003c\/span\u003eISO 527-3, is similar to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eASTM D882\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebut cannot be considered technically equivalent, as the ISO allows additional specimen geometries, requires different test speeds and the use of an extensometer or gauge marks on the specimen. According to the ASTM standard, use of an extensometer is optional.\u003c\/p\u003e\n\u003cp\u003eTensile tests on plastics with a specimen thickness greater than 1.0 mm (0.04 in) are performed in accordance with test method\u003cspan\u003e \u003c\/span\u003eASTM D638.\u003cbr\u003e\u003cbr\u003eMore information about ASTM D882\u003cspan style=\"font-size: 0.875rem;\"\u003e on \u003ca href=\"https:\/\/www.zwickroell.com\/industries\/plastics\/thin-sheeting-and-plastic-films\/astm-d882-film-tensile-test\/\" target=\"_blank\" rel=\"noopener\"\u003eZwickRoell.com\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"zwickiline","title":"zwickiLine Z0.5 TH","description":"\u003ch3 class=\"ce-header--large ce-header--left\"\u003eUniversal Testing Machine for Small Test Loads up to 0.5 kN\u003c\/h3\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eThis configuration of the zwickiLine 0.5 kN—a compact, high-quality single-column materials testing machine—is designed for standard low-force testing of plastic films, sheets, packaging films, adhesives, glued seams, laminates, and flexible bonded assemblies.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eEasy to use, transportable, and space-saving, the zwickiLine 0.5 kN fits easily on a laboratory table while still delivering the performance needed for reliable materials testing. Its lightweight design, small footprint, and modular construction make it a practical solution for laboratories that need a flexible, cost-effective testing system without compromising on quality.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eThe system is equipped with a 500 N ZwickRoell Xforce P load cell, testControl II electronics, and testXpert testing software with predefined standard test programs for accurate, repeatable, reproducible, and traceable results.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eKey features of the ZwickiLine 0.5kN include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eForce range: 2 N to 500 N\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eTypical specimen dimensions:\u003c\/span\u003e\u003c\/li\u003e\n\u003cul type=\"circle\"\u003e\n\u003cli style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level2 lfo1; tab-stops: list 1.0in;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eThickness: 0–6 mm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level2 lfo1; tab-stops: list 1.0in;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eWidth: 0–30 mm\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eHigh-accuracy Xforce load cell with a wide measurement range and resistance to transverse forces, bending moments, and torsional influences\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003ePrecise travel measurement and positioning through advanced drive technology and machine compliance correction\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eUser-friendly testXpert software with predefined standards-based test methods\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eCompatible with standard PCs and notebooks without special expansion cards\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eTwo standard configurations are available:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoTableGrid\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\" style=\"border-collapse: collapse; border: none; mso-yfti-tbllook: 1184; mso-padding-alt: 0in 5.4pt 0in 5.4pt; mso-border-insideh: none; mso-border-insidev: none;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd width=\"252\" valign=\"top\" style=\"width: 188.75pt; border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-bottom-alt: solid windowtext .5pt; mso-border-right-alt: solid windowtext .5pt; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"line-height: normal; margin: 6.0pt 0in 6.0pt 0in;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eConfiguration\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"372\" valign=\"top\" style=\"width: 278.75pt; border: none; border-bottom: solid windowtext 1.0pt; mso-border-left-alt: solid windowtext .5pt; mso-border-bottom-alt: solid windowtext .5pt; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"line-height: normal; margin: 6.0pt 0in 6.0pt 12.75pt;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eRecommended Use\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd width=\"252\" valign=\"top\" style=\"width: 188.75pt; border: none; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-right-alt: solid windowtext .5pt; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"line-height: normal; margin: 6.0pt 0in 6.0pt 0in;\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003ezwickiLine 500 N with \u003cb\u003escrew grips\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"372\" valign=\"top\" style=\"width: 278.75pt; border: none; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"line-height: normal; margin: 6.0pt 0in 6.0pt 12.75pt;\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eA flexible manual gripping solution for standard film, sheet, adhesive, laminate, and packaging material testing. Ideal for laboratories with moderate testing volumes and manual specimen handling.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd width=\"252\" valign=\"top\" style=\"width: 188.75pt; border: none; border-right: solid windowtext 1.0pt; mso-border-right-alt: solid windowtext .5pt; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"line-height: normal; margin: 6.0pt 0in 6.0pt 0in;\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003ezwickiLine 500 N with \u003cb\u003epneumatic grips\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"372\" valign=\"top\" style=\"width: 278.75pt; border: none; mso-border-left-alt: solid windowtext .5pt; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"line-height: normal; margin: 6.0pt 0in 6.0pt 12.75pt;\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eDesigned for higher testing throughput and improved operator convenience. Pneumatic grips provide fast specimen loading and consistent gripping force, making them well suited for sensitive or difficult-to-handle materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eBoth configurations provide a standardized ZwickRoell testing solution with defined scope, proven performance, and direct online ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eCleanroom use:\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003e zwickiLine systems can meet requirements for class 5 and class 6 cleanrooms in selected force ranges. Please confirm suitability for your specific application before ordering.\u003c\/span\u003e\u003c\/p\u003e","brand":"ZwickRoell","offers":[{"title":"Screw Grips (Simple) \/ Factory Calibrated (no extra cost)","offer_id":50782330192039,"sku":null,"price":26100.0,"currency_code":"EUR","in_stock":true},{"title":"Screw Grips (Simple) \/ ISO","offer_id":50779781759143,"sku":null,"price":26558.0,"currency_code":"EUR","in_stock":true},{"title":"Screw Grips (Simple) \/ DAkkS","offer_id":50782273110183,"sku":null,"price":26917.0,"currency_code":"EUR","in_stock":true},{"title":"Pneumatic grips (Comfortable) \/ Factory Calibrated (no extra cost)","offer_id":50782330224807,"sku":null,"price":27800.0,"currency_code":"EUR","in_stock":true},{"title":"Pneumatic grips (Comfortable) \/ ISO","offer_id":50779781791911,"sku":null,"price":28258.0,"currency_code":"EUR","in_stock":true},{"title":"Pneumatic grips (Comfortable) \/ DAkkS","offer_id":50782273142951,"sku":null,"price":28617.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/2688\/5031\/files\/ZR_1462_1__20MB_or_less.png?v=1782913430"},{"product_id":"zwickiline-z0-5-th-na","title":"zwickiLine Z0.5 TH","description":"\u003ch3 class=\"ce-header--large ce-header--left\"\u003eUniversal Testing Machine for Small Test Loads up to 0.5 kN\u003c\/h3\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eThis configuration of the zwickiLine 0.5 kN—a compact, high-quality single-column materials testing machine—is designed for standard low-force testing of plastic films, sheets, packaging films, adhesives, glued seams, laminates, and flexible bonded assemblies.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eEasy to use, transportable, and space-saving, the zwickiLine 0.5 kN fits easily on a laboratory table while still delivering the performance needed for reliable materials testing. Its lightweight design, small footprint, and modular construction make it a practical solution for laboratories that need a flexible, cost-effective testing system without compromising on quality.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eThe system is equipped with a 500 N ZwickRoell Xforce P load cell, testControl II electronics, and testXpert testing software with predefined standard test programs for accurate, repeatable, reproducible, and traceable results.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eKey features of the ZwickiLine 0.5kN include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eForce range: 2 N to 500 N\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eTypical specimen dimensions:\u003c\/span\u003e\u003c\/li\u003e\n\u003cul type=\"circle\"\u003e\n\u003cli style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level2 lfo1; tab-stops: list 1.0in;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eThickness: 0–6 mm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level2 lfo1; tab-stops: list 1.0in;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eWidth: 0–30 mm\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eHigh-accuracy Xforce load cell with a wide measurement range and resistance to transverse forces, bending moments, and torsional influences\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003ePrecise travel measurement and positioning through advanced drive technology and machine compliance correction\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eUser-friendly testXpert software with predefined standards-based test methods\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eCompatible with standard PCs and notebooks without special expansion cards\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eTwo standard configurations are available:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoTableGrid\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\" style=\"border-collapse: collapse; border: none; mso-yfti-tbllook: 1184; mso-padding-alt: 0in 5.4pt 0in 5.4pt; mso-border-insideh: none; mso-border-insidev: none;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd width=\"252\" valign=\"top\" style=\"width: 188.75pt; border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-bottom-alt: solid windowtext .5pt; mso-border-right-alt: solid windowtext .5pt; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"line-height: normal; margin: 6.0pt 0in 6.0pt 0in;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eConfiguration\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"372\" valign=\"top\" style=\"width: 278.75pt; border: none; border-bottom: solid windowtext 1.0pt; mso-border-left-alt: solid windowtext .5pt; mso-border-bottom-alt: solid windowtext .5pt; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"line-height: normal; margin: 6.0pt 0in 6.0pt 12.75pt;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eRecommended Use\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd width=\"252\" valign=\"top\" style=\"width: 188.75pt; border: none; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-right-alt: solid windowtext .5pt; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"line-height: normal; margin: 6.0pt 0in 6.0pt 0in;\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003ezwickiLine 500 N with \u003cb\u003escrew grips\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"372\" valign=\"top\" style=\"width: 278.75pt; border: none; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"line-height: normal; margin: 6.0pt 0in 6.0pt 12.75pt;\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eA flexible manual gripping solution for standard film, sheet, adhesive, laminate, and packaging material testing. Ideal for laboratories with moderate testing volumes and manual specimen handling.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd width=\"252\" valign=\"top\" style=\"width: 188.75pt; border: none; border-right: solid windowtext 1.0pt; mso-border-right-alt: solid windowtext .5pt; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"line-height: normal; margin: 6.0pt 0in 6.0pt 0in;\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003ezwickiLine 500 N with \u003cb\u003epneumatic grips\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"372\" valign=\"top\" style=\"width: 278.75pt; border: none; mso-border-left-alt: solid windowtext .5pt; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"line-height: normal; margin: 6.0pt 0in 6.0pt 12.75pt;\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eDesigned for higher testing throughput and improved operator convenience. Pneumatic grips provide fast specimen loading and consistent gripping force, making them well suited for sensitive or difficult-to-handle materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eBoth configurations provide a standardized ZwickRoell testing solution with defined scope, proven performance, and direct online ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eCleanroom use:\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos Display',sans-serif; mso-ascii-theme-font: major-latin; mso-fareast-font-family: 'Times New Roman'; mso-hansi-theme-font: major-latin; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003e zwickiLine systems can meet requirements for class 5 and class 6 cleanrooms in selected force ranges. Please confirm suitability for your specific application before ordering.\u003c\/span\u003e\u003c\/p\u003e","brand":"ZwickRoell","offers":[{"title":"Screw Grips (Simple) \/ Factory Calibrated (no extra cost)","offer_id":50928097886375,"sku":null,"price":26100.0,"currency_code":"EUR","in_stock":true},{"title":"Screw Grips (Simple) \/ ASTM","offer_id":50928103588007,"sku":null,"price":26100.0,"currency_code":"EUR","in_stock":true},{"title":"Pneumatic grips (Comfortable) \/ Factory Calibrated (no extra cost)","offer_id":50928097984679,"sku":null,"price":27800.0,"currency_code":"EUR","in_stock":true},{"title":"Pneumatic grips (Comfortable) \/ ASTM","offer_id":50928103620775,"sku":null,"price":26100.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/2688\/5031\/files\/ZR_1462_1__20MB_or_less.png?v=1782913430"}],"url":"https:\/\/shop.zwickroell.com\/en-us\/collections\/astm-d882-film-tensile-test.oembed","provider":"ZwickRoell","version":"1.0","type":"link"}